Descriptions : The FV2000 General Purpose Wall-Mount Clamp-on Ultrasonic Flowmeter is the first member of the 3rd generation ultrasonic flowmeters from sonic. Compared with the predecessors, the 3rd generation ultrasonic flowmeters offer better performances and a richer feature set, all at a lower price. The FV2000 is designed to be installed at a fixed location for long-term flow measurement from outside of a pipe that carries pure liquids and liquids with minor suspended particles. It utilizes cutting-edge technologies such as advanced transducer design, low voltage transmission, digital signal processing, and self adaptation to achieve high performance. As QUALITY is of crucial importance, all transducers are carefully paired, and all flowmeters are wet-calibrated in the factory to further ensure system accuracy and reliability. FV2000 provides versatile input/output interfaces, such as digital and relay outputs, batch control, alarm, flow totalizing, 4-20mA output, and optional RTD interface for thermal energy measurement, which can be easily used by a host computer or a flow controller for process monitoring and control. Besides, the isolated built-in RS-485 port and the optional GPRS/GSM module make remote flow monitoring easy and reliable. Due to the non-intrusive nature of the clamp-on technology, there is no pressure drop, no moving parts, no leaks, no risk of contamination, no risk of corrosion, no pressure dependency and no blockage on the flow. The installation is very simple and requires no special skills or tools. The cost of installation, operation, and maintenance is lower than that of conventional flowmeters. FV2000 is an ideal choice for demanding applications where low-cost, high-performance and non-intrusiveness are a must. A pplications include, but are not limited to, liquid process control, water flow measurement (hot/chill water, city water, sea wat beverages, and many other liquids. |
Main Unit | Repeatability | Better than ±0.5% | Accuracy | Better than ±1%. Can reach ±0.5 when on-situ calibration is available | Response Time | 0.5s. 0-99s user-programmable | Velocity | -52ft/s - +52 ft/s (-16m/s - +16 m/s), bi-directional. | Display | LCD with backlight. 2 x 20 character display. Displays instantaneous flow rate, totalized flow rate, velocity, sound speed, time, analog inputs, etc. | Units | English (U.S.) or metric | Signal Outputs | Current output: 4-20mA or 0-20mA. Impedance 0-1k. Accuracy 0.1% | Isolated OCT output: can be programmed as pulse output for flow totalizers or frequency output for flow rate | Relay: can be programmed to control alarm, valve or batch process | Sound alarm | Signal Inputs | One channel 4-20mA current input: for signals such as temperature, pressure, liquid level. etc. Accuracy 0.1%. Additional analog input channels are available upon request Two RTD temperature channels (refer to model STUF-300R1B): to accommodate two PT100 temperature sensors. Thermal energy measurement and calculation functionalities implemented. | Recording | Automatically records the following information:1) The totalizer data of the last 64 days / 64 months / 64 years;2) The power time and corresponding flow rate of the last 64 power-on and -off events; 3) Allows for manual or automatic flow loss compensation; 4) The instrument working status of the last 64 days. | Communication Interface | Isolated RS-485. Supports the MODBUS protocol. Optional GPRS / GSM module for networking, remote monitoring and remote control (for model STUF-300FNB only) | Enclosure | Protection Class: IP65 (NEMA 4X) Explosive Proof Class: ExdIIBT4 (for model STUF-300F2B only) | Liquids | Liquid Types | Virtually all commonly used liquids (full pipe) | Liquid Temp | -40˚F ~ 312˚F (-40˚C ~ 155˚C), depending on transducer type | Suspension concentration | < 20,000ppm. Particle or air bubble size should not exceed 75um | Pipe | Pipe Size | 1" ~ 240"For pipe size of 1” and smaller, the STUF-300FxG flow-cell flowmeter is recommended | Pipe Material | All metals, most plastics, fiber glass, etc. Allows for pipe liner. | Pipe Straight Run | 15D or longer preferred, where D is pipe diameter. If a pump or valve is near upstream, the straight pipe section should be > 30D. | Cable | Shielded transducer cable. Standard length 15ft (5m). Can be extended to 1640ft (500m). Contact the manufacturer for longer cable requirement. Cable should not be laid in parallel with high-voltage power lines. Neither should it be close to strong interference sources such as power transformers. | Environment | Temperature | Main unit: 0˚F - 176˚F (-30˚C - 80˚C) | Transducer: -40˚F ~ 212˚F (-40˚C ~ 100˚C) for the standard version; -40˚F ~ 312˚F (-40˚C ~ 155˚C) for the higher temperature version | Humidity | Main unit: 85% RH | Transducer: water-immersible, water depth less than 10’ (3m) | Power | AC: 90V / 260V, or, DC: 18VDC-36VDC<1 Watt | Weight | Standard main unit: 4 lb (2 kg), Network main unit: 5 lb (2.5 kg) | |